Models:30A 40A 50A 60A |
30A |
40A |
50A |
60A |
Maximum PV input power |
12V system |
400W |
480W |
600W |
720W |
24V system |
720W |
960W |
1200W |
1440W |
36V system |
1000W |
1400W |
1800W |
2100W |
48V system |
1200W |
1700W |
2200W |
2800W |
PV open circuit voltage requirement(Make sure the Voc of PV meeting the requirement as right. Voc is 1.5 or 2 times than bettery, then it's best efficiency.)
|
12V system |
DC20V-DC80V |
24V system |
DC37V-DC105V |
36V system |
DC50V-DC160V |
48V system |
DC72V-DC160V |
Maximum PV open circuit voltage (Voc) |
12V/24V/36V/48V system |
DC190V(The controller can't work at this voltage of long duration that will break controller.Please refer to input voltage from PV |
Basic Parameter |
MPPT controller |
12V system |
24V system |
36V system |
48V system |
Overcharging protection voltage |
15v |
30V |
45V |
60V |
System voltage automatic recognition |
DC9V-DC15V |
DC18V-DC29V |
DC30V-DC39V |
DC40V-DC60V |
Max efficiency |
>98.1%(Voc is 1.5 or 2 times than baattery, then it's best efficiency) |
PV utilization |
d>99% |
Protection function |
Temperature function |
75℃ |
Fan-on temperature |
>40℃ |
Fan-off temperature |
<35℃ |
Properties |
Size |
235*188*100mm |
Net weight(kg) |
1.1 |
Gross weight(kg) |
1.6 |